Files
retroSoC/tests/rtl/clint_tb.sv
T
maksyuki 4b40dbf262 feat: add CLINT peripheral support and related enhancements
- Updated the formal file list generator to include CLINT source files.
- Added CLINT timebase to the clock and reset domains configuration.
- Enhanced the SOC topology generation to include CLINT interrupts and their mappings.
- Introduced a new CLINT testbench to validate multi-hart and timebase functionality.
- Modified the software build configuration to define CLINT timebase frequency.
- Updated the RCU module to integrate CLINT timebase generation.
- Adjusted the IRQ configuration to reflect changes in CLINT interrupt signals.
- Added user-visible flags for interrupts in the topology configuration.
- Enhanced the clock reset domain checks to include CLINT timebase.
- Updated the memory map tests to validate CLINT peripheral integration.
2026-08-08 13:31:48 +08:00

136 lines
3.9 KiB
Systemverilog

`timescale 1ns / 1ps
module clint_tb;
logic clk_i = 1'b0;
logic ref_clk_i = 1'b0;
logic rst_n_i = 1'b0;
logic tick_i = 1'b0;
logic timebase_tick;
logic [31:0] value;
integer timebase_tick_count = 0;
ribp_if ribp ();
clint_if #(.HART_NUM(2)) clint ();
always #5 clk_i = ~clk_i;
always #2 ref_clk_i = ~ref_clk_i;
always @(posedge clk_i) begin
if (timebase_tick) timebase_tick_count <= timebase_tick_count + 1;
end
clint_timebase #(
.REF_CLK_HZ (4),
.TIMEBASE_HZ(1)
) u_timebase (
.ref_clk_i (ref_clk_i),
.ref_rst_n_i(rst_n_i),
.sys_clk_i (clk_i),
.sys_rst_n_i(rst_n_i),
.tick_o (timebase_tick)
);
ribp_clint #(
.HART_NUM(2)
) u_dut (
.clk_i,
.rst_n_i,
.timebase_tick_i(tick_i),
.ribp,
.clint
);
task automatic ribp_write(input logic [31:0] address, input logic [31:0] data,
input logic [3:0] strobe, input logic expected_error);
begin
@(negedge clk_i);
ribp.valid = 1'b1;
ribp.addr = address;
ribp.wdata = data;
ribp.wstrb = strobe;
do @(negedge clk_i); while (!ribp.ready);
if (ribp.resp_err !== expected_error) begin
$fatal(1, "write %h error=%b expected=%b", address, ribp.resp_err, expected_error);
end
ribp.valid = 1'b0;
ribp.wstrb = '0;
end
endtask
task automatic ribp_read(input logic [31:0] address, output logic [31:0] data,
input logic expected_error);
begin
@(negedge clk_i);
ribp.valid = 1'b1;
ribp.addr = address;
ribp.wdata = '0;
ribp.wstrb = '0;
do @(negedge clk_i); while (!ribp.ready);
data = ribp.rdata;
if (ribp.resp_err !== expected_error) begin
$fatal(1, "read %h error=%b expected=%b", address, ribp.resp_err, expected_error);
end
ribp.valid = 1'b0;
end
endtask
task automatic pulse_tick;
begin
@(negedge clk_i);
tick_i = 1'b1;
@(negedge clk_i);
tick_i = 1'b0;
end
endtask
initial begin
ribp.valid = 1'b0;
ribp.addr = '0;
ribp.wdata = '0;
ribp.wstrb = '0;
repeat (4) @(posedge clk_i);
rst_n_i = 1'b1;
ribp_read(32'h0000_0000, value, 1'b0);
if (value != 32'd0 || clint.software_irq_o != 2'b00) begin
$fatal(1, "MSIP reset state is invalid");
end
ribp_read(32'h0000_4000, value, 1'b0);
if (value != 32'hFFFF_FFFF) $fatal(1, "MTIMECMP low reset state is invalid");
ribp_read(32'h0000_4004, value, 1'b0);
if (value != 32'hFFFF_FFFF || clint.timer_irq_o != 2'b00) begin
$fatal(1, "MTIMECMP high reset state is invalid");
end
ribp_write(32'h0000_0004, 32'h0000_0001, 4'h1, 1'b0);
if (clint.software_irq_o != 2'b10) $fatal(1, "hart 1 MSIP did not assert");
ribp_write(32'h0000_0004, 32'h0000_0000, 4'h1, 1'b0);
if (clint.software_irq_o != 2'b00) $fatal(1, "hart 1 MSIP did not clear");
ribp_write(32'h0000_BFFC, 32'd0, 4'hF, 1'b0);
ribp_write(32'h0000_BFF8, 32'd10, 4'hF, 1'b0);
ribp_read(32'h0000_BFF8, value, 1'b0);
if (value != 32'd10) $fatal(1, "MTIME write/read failed: %h", value);
ribp_write(32'h0000_4004, 32'd0, 4'hF, 1'b0);
ribp_write(32'h0000_4000, 32'd12, 4'hF, 1'b0);
pulse_tick();
pulse_tick();
repeat (2) @(posedge clk_i);
if (clint.timer_irq_o[0] != 1'b1) $fatal(1, "hart 0 timer IRQ did not assert");
if (clint.timer_irq_o[1] != 1'b0) $fatal(1, "hart 1 timer IRQ asserted unexpectedly");
ribp_write(32'h0000_4001, 32'd0, 4'hF, 1'b1);
ribp_read(32'h0000_0010, value, 1'b1);
if (value != 32'd0) $fatal(1, "invalid read did not return zero");
repeat (20) @(posedge clk_i);
if (timebase_tick_count < 2) begin
$fatal(1, "reference-clock timebase did not produce synchronized ticks");
end
$display("CLINT standard map, multi-hart, IRQ, error, and timebase test passed");
$finish;
end
endmodule